And I hope that you put lock washers under the nuts on the other side. If a nut comes loose you'll have a high resistance spot. While 20-30A is flowing through there, you'll get enough heat to light that wood on fire.
It is hard to judge size, but that toggle switch looks like it might be rated in the area of 5A to 10A max. (Probably closer to 5 than 10.) It might live if you never operated it while the motors are running. Still, it is going to be a weak link in the chain.
Comments
Rana has a point. Well, a couple maybe.
It is hard to judge size, but that toggle switch looks like it might be rated in the area of 5A to 10A max. (Probably closer to 5 than 10.) It might live if you never operated it while the motors are running. Still, it is going to be a weak link in the chain.
Ho can you do such a big mistake of putting on-off toggle switch in the main lipo path !
Just bypass it otherwise you will be in trouble.